Home Contact Us Site Map
 
 
 

Cryogenic Elaton

Program Directive
To design, fabricate, and test a spaceflight qualified tunable Fabry-Perot etalon.

Scott Lindemann - Program Manager for Cryogenic Etalon Program - Michigan Aerospace Corporation
Program Manager
Scott Lindemann
scottlindemann@michiganaerospace.com

(734) 975-8777 x106
 

Program Description
Michigan Aerospace Corporation is presently contracted with NASA Langley Spaceflight Center to design, fabricate and test a spaceflight qualified tunable Fabry-Perot etalon. This device will be operated at 77 Kelvin from 7 - 11 microns. Tuning is accomplished via this use of ferroelectric single crystals and will provide a range of travel of approximately 20 microns at operating temperature. Zinc Selenide is used for all transmitting elements. Titanium (Ti-6Al-5V Grade 5) is used for the etalon mount due to its low density, high strength, and coefficient of thermal expansion.

Cryogenic Etalon Requirements and Parameters
Parameter
Desired
Minimum
Design Projected
Wavelength
9-12um
-
-
Gap
-
-
3.7mm
Finesse
20
12
19.3
Transmission
11%
8%
8.10%
Resolution
0.07 cm-1
6.32 Angstroms at 9.5um
6.32 Angstroms at 9.5um
Reflectivity
0.8
0.6-0.9
0.85
Dynamic Range
25um
5um
(1/2 wavelength)
20.5
Free Spectral Range
Maximize
-
12.2nm

Thermal Analysis of Cryogenic Etalon - Michigan Aerospace Corporation

 


Copyright © 2000 Michigan Aerospace Corporation. All rights reserved.
Send any questions or comments to
webmaster@michiganaerospace.com